HP ProLiant DL380 Gen9 Maintenance And Service Manual

Verify that the processor is fully seated in the processor retaining bracket by visually inspecting the processor installation guides on either side of the processor. Follow the instructions on the website to update the system ROM. Page 17 Optional—Parts for which customer self repair is optional. System Battery Remove the controller. Removal and replacement procedures Page 65 Install the processor. Release the full-length expansion board retainer To remove the component:

Product Description

Currency Converter

To prevent damage to the server or expansion boards, power down the server and remove all AC power cords before removing or installing the PCI expansion cage. QuickSpecs on the HP website http: HP iLO The iLO 4 subsystem is a standard component of HP ProLiant servers that simplifies initial server setup, server health monitoring, power and thermal optimization, and remote server administration.

The iLO 4 subsystem includes an intelligent microprocessor, secure memory, and a dedicated network interface. HP Active Health System does not parse or change operating system data from third-party error event log activities, such as content created or passed through by the operating system. The data that is collected is managed according to the HP Data Privacy policy. For more information see the HP website http: The Embedded Diagnostics option can run comprehensive diagnostics of the server hardware, including processors, memory, drives, and other server components.

HP SSA exists in three interface formats: Although all formats provide support for configuration tasks, some of the advanced tasks are available in only one format. When the operating system is functioning properly, the system periodically resets the timer.

Error Messages provides a list of error messages and information to assist with interpreting and resolving error messages on ProLiant servers and server blades. To view the guide, select a language: The display enables diagnosis with the access panel installed. NMI functionality An NMI crash dump enables administrators to create crash dump files when a system is hung and not responding to traditional debug mechanisms.

To avoid damage to the equipment, do not operate the server for extended periods of time if the server does not have the optimal number of fans installed. Although the server might boot, HP does not recommend operating the server without the required fans installed and operating. If the server hardware detects a critical temperature level before an orderly shutdown occurs, the server performs an immediate shutdown.

Flashing blue The drive carrier firmware is being updated or requires an update. The approved hardware configurations for this system are listed on the HP website http: Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback mailto: Include the document title and part number, version number, or the URL when submitting your feedback.

Page of Go. Page - Non-hot-plug PCI riser board slot defini This guide describes identification and maintenance procedures, diagnostic tools, specifications, and requirements for hardware components and. HP assumes you are qualified in the servicing of computer equipment, trained in. Table of Contents Add to my manuals Add. Installing and configuring proliant essentials recovery server option rso with oracle database servers 13 pages.

Brocade fabric os command reference manual supporting fabric os v6. Summary of Contents for HP ProLiant DL Gen9 Page 1 This guide describes identification and maintenance procedures, diagnostic tools, specifications, and requirements for hardware components and software. Table Of Contents Drive blank Page 4 Front panel LEDs and buttons Page 13 Customer self repair Page 14 Customer self repair Page 15 Customer self repair Illustrated Parts Catalog Illustrated parts catalog Mechanical components HP continually improves and changes product parts.

Page 17 Optional—Parts for which customer self repair is optional. Page 19 Illustrated parts catalog System Components System components HP continually improves and changes product parts. Page 24 Optional—Parts for which customer self repair is optional. Page 26 Illustrated parts catalog Removal And Replacement Procedures Extend the server from the rack on page Safety Considerations Release the full-length expansion board retainer.

Server Warnings And Cautions This symbol indicates the presence of electric shock hazards. Pcie Riser Blank Remove the air baffle. Power Supply Blank Remove the drive. Hp w Flex Slot Hot Plug Battery Backup Module To reduce the risk of personal injury from hot surfaces, allow the power supply or power supply blank to cool before touching it.

Optical Drive Optical drive To remove the component: Page 42 Remove the optical drive. Hot-plug Fan Before replacing the component, install the optical drive bracket, retained from the optical drive you are replacing. Fan Cage Remove the fan. Flexiblelom Remove the fan cage.

Universal Media Bay Remove the drive cage. Systems Insight Display Remove the drive backplane. Half-length Expansion Board To remove the component: Heatsink 3-slot riser cage 2-slot riser cage To replace the component, reverse the removal procedure. Page 62 Extend the server from the rack on page Processor MHz, or MHz.

Page 64 Remove the server from the rack on page Page 65 Install the processor. Dimms Press and hold the processor retaining bracket in place, and then close each processor locking lever. Hp Smart Storage Battery System Battery Remove the controller. This only covers the rear half of the motherboard, is used to support the riser cards and is much easier to remove and replace.

The huge cooling shroud in the G6 also gets its marching orders. There's now a smaller transparent cover that fits around the centralised processor sockets rather than over them. This arrangement seems to work well. With four of the six possible hot-plug cooling fans in place, we found this server to be nearly silent. As with the G6, you have a good choice of expansion options - the single riser has three PCI Express slots.

For sheer storage capacity, the DL is still the best in its class with room at the front for up to sixteen hot-swap drive bays. However, upgrading to sixteen drives requires replacing the blanking plate on the front panel with a second eight-drive bay.

The MB cache module has a plug for an optional battery backup pack. Virtualisation fans get a nod as the server has both internal USB and SD memory card slots for booting from an embedded hypervisor. But with the host's ssh shell, you can pull the server's product name and HP part number. At the shell prompt, type:. As for the disks and disk types comprising the array, the normal approach is to use the HP Insight Agents and use hpacucli when using a full OS, or one of the methods listed here.

That's not an option under ESXi, though. You don't need a generic live CD to obtain full hardware specifications. The servers come with them. Running that will provide full insight into the hardware specs and RAID configuration. I'm sure there is a more elegant way, but to find out what kind of disks you have you can do an fdisk -l on the command line, and it tells you the model number and serial number of the disk:. You may be able to get all of this information from within vCenter using the Hardware Status Page.

Try to use esxcfg-info with -w key over ssh or console. It command returns a lot of info, some of it is unique.

Your Answer

Leave a Reply